Suction pressure for 410a - connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid …

 
Mar 26, 2024 · The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load. . Big 10 women's basketball tournament bracket

the heat content of the return air (including the sensible temperature) drops, the saturated suction temperature will drop, resulting in a drop in suction pressure. As the suction pressure falls to 120psig the APR Control will begin to open and attempt to stabilize the system suction pressure at approximately 120psig.Apr 14, 2015 · Let's get started and see what we can do.Most manufacturers recommend charging by super heat and subcoolimg rather than pressures alone,and will vary slightly by manufacturer but as a rule low side of about 110 and high side about 280at 70 degree ambient. This will of course increase as temp warms up.ON an 85 degree day,probably 130 to 135 and ... “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 …In this HVAC Training Video, I Show If You Can Check The Refrigerant Charge on an Inverter Mini-Split Ductless Unit on a Service Call by measuring superheat ...Temperature (°F): R410A Pressure (psig): -60 °F. 0.9 psig. -55 °F. 1.8 psig. -50 °F. 4.3 psig.These liquid-line restrictions all cause the evaporator, compressor, and condenser to be starved of refrigerant. This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control;Suction pressure control — loss of charge P170AA-400C SPST Open Low 100 470 690 Fan cycling for head P170CA-400C SPST Open High 200 610 690 ... PRESSURE CONTROLS COMPATIBLE WITH R-410A COMMERCIAL REFRIGERATION CONTROLS * Maritime models for use with corrosive media. ** Low-flow model. Forane 410A Pressure Temperature Chart. Saturation Pressure-Temperature Data for R-410A (psig)*. Constants for vapor pressure of saturated vapor (dew point), p g: A = –1.440004 E+00 E = –3.521484 E+00 B = –6.865265 E+00 F = –7.750000 E+00 C = –5.354309 E–01 X o = 2.086902 E–01 D = –3.749023 E+00 Because both pressure and temperature appear in the reduced form in the equation, the same constants can be used for either SI or ... liquid and suction lines covering total linear = 200 ft. equivalent lengths up to 240 ft. The philosophy in designing a refrigerant piping system can be summed up as follows: Liquid lines should be sized as small as possible without exceeding the recommended maximum pressure drop of 50 PSI for R-410A. Liquid line pressureJul 21, 2009 · R-410A refrigiant. The Suction pressure temperature chart in the Condensing Unit installation & service reference that came with the unit only goes up to 80 psig, yet I'm seeing 135 psig at the low side service valve. Looking elwhere I found that 135 psig is 47F. High side 285 psig which is 92F. Spec is SH 7-9F and SC 7-9F (using TXV). SC: 92F ... Weather forecasters can tell what the weather will be by reading the barometric pressure, but how does it work? Advertisement You've probably experienced the scenario where, on a c...As an HVAC technician or someone interested in air conditioning systems, understanding the key factors that impact 410A refrigerant pressures is crucial. The proper functioning of ...Liquid pressure for 410a on a 85 degree day is: 255.4psi. Vapor pressure for 410a on a 85 degree day is: 254.6 psi. Example 2. What should the 410a pressures on a 50, 65, 70 degree day be? On a 50 degree day. Liquid pressure: 143.2 psi. Vapor pressure: 142.6 psi. On a 65 degree day. Liquid pressure:185.8psi. Vapor pressure: 185.2 psi. My very wild guess would be an obstruction somewhere in the coil or suction line. You eliminated every other cause for a high low pressure (Air flow, refrigerant, compressor txv). I would try touching and observing the piping for any sudden change in temperature. Student here, so take this with a grain of salt. 2. An essential tool for charging 410A by subcooling is a set of HVAC gauges. These gauges allow you to measure the pressure in your system, helping you determine the correct refrigerant charge. Make sure to use gauges specifically designed for use with 410A refrigerant.Liquid pressure for 410a on a 85 degree day is: 255.4psi. Vapor pressure for 410a on a 85 degree day is: 254.6 psi. Example 2. What should the 410a pressures on a 50, 65, 70 degree day be? On a 50 degree day. Liquid pressure: 143.2 psi. Vapor pressure: 142.6 psi. On a 65 degree day. Liquid pressure:185.8psi. Vapor pressure: 185.2 psi.Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both sides, begin from 365 on suction and liquid lines and …A R-410A evaporator running below 100 psig will freeze-up just like its R-22 cousin. One of the most common causes of low suction pressure is loss of critical …Heating mode: outside temp >65F: Run AUX only - lock out compressor (avoid high pressure) outside temp >10F and <65F: Run compressor and AUX as needed. outside temp <10F: Run AUX only - lock out compressor (avoid defrost cycling) Cooling mode: outside temp <60F: lock out compressor, run air handler fan only.What should be the 410a suction pressure? As shown in Figure 1 on the next page, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi with R-410A. HFC-32 and HFC-125 are mixed together in R-410A, which is an azeotropic mixture.Turn the thermostat to cool and set the target temperature at least 10 degrees lower than the indoor temperature. Let the system operate for at least 10 minutes to let pressures equalize. Record the suction line pressure. Use a temperature measuring device to measure the temperature of the suction line.Jul 27, 2012 ... Comments2 ; Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips! AC Service Tech LLC · 1.2M views ; What Should my AC ...pressure relief for R-410A will open at 550-625 psig. Suction and discharged pressure are 40% to 70% greater than R-22 and the discharge temperature of R-410A is lower due to its higher vapor heat capacity. Never heat an R-410A cylinder over 125ºF. • The high-pressure switch will open at 610 psig (plus or minus 10 psig), andFilter is new. suction pressure is about 85 which seems low and head pressure is about 230 which seems ok. Super heat goes all over the place from 6 to 16. do you think I have a refrigerant restriction? Any help is greatly appreciated. Thanks. ... My 410a system keeps freezing up. Filter is new. suction pressure is about 85 which …Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation.The pressures were still at the 130 on suction side and 335 on the high side, but the cooling has gone away, suction side does not get cool. It has a metering orifice, no txv So, I thought I may be overcharged, since the liquid got in. I reclaimed some 410a (not measured) which sent the pressure too 150 on suction side and 365 on high side ...Jan 16, 2023 · The temperature pressure charts in HVAC help in troubleshooting various problems with air conditioning systems such the the head and suction pressure, liquid lines and troubleshooting superheat and subcooling. Here are a few examples on using this chart. Example 1. What are the 410a pressures on a 85 degree day? Here are the steps to find the value pressure relief for R-410A will open at 550-625 psig. Suction and discharged pressure are 40% to 70% greater than R-22 and the discharge temperature of R-410A is lower due to its higher vapor heat capacity. Never heat an R-410A cylinder over 125ºF. • The high-pressure switch will open at 610 psig (plus or minus 10 psig), andA refrigerator sealed system is a system in which refrigeration occurs. It is composed of the suction tube, metering device evaporator, condenser and compressor. The compressor inc...This is a table that tells you precisely what the pressure of R404A is at a certain temperature. At the low end, the pressure of 404A is 0.9 psig. At the high end, ... R410A PT Chart: -60°F To +155°F Pressure Temperature Chart; R22 PT Chart: Pressure Temperature Chart For -60°F To +155°F; R454B PT Chart: Pressures At -40°F To 150°F ...ESIEN05-04 Disassembly and Maintenance 1.11.1 Removal of Suction Grille Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Procedure: Step Procedure Points 1 Removing the suction grille Push the buttons and pull down Push the 2 buttons When closing, push up the simultaneously and pul...1. Even though this is not the cause of high suction, Clean The Evaporator, because it needs to be clean. If it's dirty, it causes LOW suction pressure, and causes inexperienced techs to overcharge a system. 2. Just for kicks, and for a learning experience, check the system vitals, and record the pressures, water temp entering and leaving the ...Table of Contents. Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, …We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning …SUCTION PRESSURE / EVAP DTD RULE OF THUMB Another common old school rule of thumb is suction pressure should be close to the outdoor temperature in a R-22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20˚-25˚ suction saturation below outdoor ambient.system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3.Unit is a 2-1/2 ton, upflow attic crawlspace. 3/4 x 3/8 copper. Suction pressure fluc 110psi to 130psi. Discharge was 370 on 90+ degree outside temp. went over all connections..all dampers are open..no air leaks drawing from attic. 10 - 12 deg temp difference across coil. Sounds as if you are low on freon.Suction pressure R410A. I ran a system today and had a suction pressure of 5 bar. I have never seen one so low on 410A and charged to manufacturers guidelines, there was frosting on suction valve and inlet/outlets to evap after a couple of minutes. Acson A5LC25CR-ACPOC-R outdoor unit connected to AHU. Quick Example: Let’s say that we have a 3-ton 16 SEER AC are using R-410A refrigerant and want to calculate R-410A superheat. With low side blue gauge on the suction line service port, we measured 130 psi pressure that correlates (according to R-410A PT chart) to about 45°F. The clamp-on thermometer shows that the saturated refrigerant ... Many servicemen experience service calls where the compressor has both a low head pressure and a high suction pressure. Often, the refrigeration equipment is still running, but the product temperature is suffering about 7 to 10°F. These calls are tough to handle because the compressor is still cooling, but not cooling to its rated capacity.Apr 1, 2024 · Here we will learn the R410A Pressure-Temperature Chart. R410A is very commonly used refrigerant that is known as AZ-20”, “Genetron R410A”, “Puron. It is patented by Honeywell. It is mostly used freon in AC systems and works as a replacement for R22. Here we will make an R410A Pressure-Temperature Chart that will help you find its ... Nov 11, 2022 · 2. Record the temperature and measure the suction pressure at the suction lines. 3. Convert the suction pressure recorded to the temperature using the temperature/ pressure Chart. 4. To calculate superheat simply subtract the two temperature values. IMPORANT: In most systems. 1. Superheat is about 10 degrees when measured at the evaporator and. 2. Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both sides, begin from 365 on suction and liquid lines and continue increasing the pressure on both sides almost to 400psi on ...After the suction line has been strapped to the joist or rafter at 8’ (2.4 m) intervals, strap the liquid line to the suction line. 8’ (2.4 m) Metal Sleeve Wire Tie (around suction line only) Floor Joist or Roof Rafter Tape or Wire Tie Tape or Wire Tie If hanging line set from a joist or rafter, use metal strapping or heavy nylon wire tiresAug 5, 2023 · Read also: R410a Pressure Chart High and Low Side. psi: Pound per square inch, unit of pressure. FAQ What is the normal suction pressure on a 404a walk in the freezer? The normal suction pressure on a 404 a walk in freezer is around 10-20 psig (10 is ideal) on the suction side if working properly. And the high side is about 180 or so. This will allow you to measure the suction line temperature during the charging process. Step 2 – Taking Measurements Measure Suction Line Temperature. With your temperature probe in place, measure the ... Refer to a 410A pressure-temperature chart or use an HVAC app to convert the high-side pressure reading to the corresponding saturation ... My very wild guess would be an obstruction somewhere in the coil or suction line. You eliminated every other cause for a high low pressure (Air flow, refrigerant, compressor txv). I would try touching and observing the piping for any sudden change in temperature. Student here, so take this with a grain of salt. 2. Nov 11, 2022 · 2. Record the temperature and measure the suction pressure at the suction lines. 3. Convert the suction pressure recorded to the temperature using the temperature/ pressure Chart. 4. To calculate superheat simply subtract the two temperature values. IMPORANT: In most systems. 1. Superheat is about 10 degrees when measured at the evaporator and. 2. The liquid line pressure at 108°F saturation temperature is 356.5 PSIG. This screenshot of the Ref Tools app shows the liquid line pressure of R410A at saturation at 108°F. Notice how the slider has been set to BUBBLE point (inside the orange box). Vapor Line Pressure: Again, we already have the return air temp data, which is 74°F.An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ...spring pressure calculation for R-410A (in SH) suction line temp PSI - sat. temp. PSI = spring pressure R410A (is in SH) when in doubt where do you mount the sensing valve?Making changes to your diet is a proven way to help control high blood pressure. These changes can also help you lose weight and lower your chance of heart disease and stroke. Maki...The internal pressure relief valve is located between the high and low side of the compressor. It is designed to open when the discharge-to-suction pressure differential exceeds 550 to 625 psid (38-43 bar). When the valve opens, hot discharge gas is routed back into the area of the motor protector to cause a trip.Hence, R410A refrigerant is considered safer than R22 refrigerant which is why it is a direct replacement for R22 refrigerant despite being slightly higher in GWP. R410A refrigerant is also a high-pressure refrigerant. The suction pressure of R410A air conditioners is usually around 125 psi (862 kPa) which is much higher than R22 air …How to Use a Pool Vacuum. Visit HowStuffWorks.com to learn more about how to use a pool vacuum. Advertisement Using a pool vacuum makes the task of cleaning the floor of the pool e...410a low suction pressure. I injected super seal in a 410a system that had a tiny leak that I could not find. 2 years later I come across the problem of low suction pressure normal head pressure. Replaced txv and had same problem. Replaced compressor and had the same problem. Could the super seal be clogging the txv or evaporator or condenser ...An essential tool for charging 410A by subcooling is a set of HVAC gauges. These gauges allow you to measure the pressure in your system, helping you determine the correct refrigerant charge. Make sure to use gauges specifically designed for use with 410A refrigerant.I have high suction pressure and slightly low to correct head pressure. It is a heat pump operating in heat mode. Filters are clean and indoor coil is clean as well. ... R410a Copeland scroll (single speed with bypass for two stages cooling). Running on high, Suction 140 psig, liquid 300 psig, superheat 9F, ... The higher pressure, and the fact that R-410A performs very much like a single component refrigerant, provide an opportunity to produce a more compact system with greater efficiency. In addition, R-410A refrigerant allows more suction line pressure drop since it is less sensitive to suction line efficiency losses. The R410A PT chart can be used to answer questions like: What are normal operating pressures for 410A? What is the pressure of r410a at 72 degrees Fahrenheit? What should gauge read for 410A? You can also use the R-410A PT chart to adequately calculate the superheat, total superheat, and subcooling temperatures.Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient.High Suction Pressure R-410a. i went to check an 3.5 ton a/c brand is a ICP (international comfort products) Model WAPL424A1, not cooling my pressures were low side 185 to 190 and high side was around 350 on a 107F hot day. It has a piston as a metering device and compressor was running at 11.50 amps and RLA is 17.25 amps.R410A Systems Run at a Different Pressure. Compared to an R22 system, an R410A air conditioner runs at a higher pressure. These systems operate at about 130 pounds per square inch (psi). ... This will contaminate the system, and the R22 will not evaporate under the higher suction pressure that R410A requires. An HVAC System …Jan 3, 2014 · Currently working on a Bremar ice maker. Just did a compressor change and thought I weigh charged it perfectly. But it's not making good ice. I have only a suction port to read the pressures, and I'm getting 300kpa at the beginning of the 8.5 min cycle, and around 240kpa by the end. It runs for 8.5miutes then goes on defrost to drop the ice made. A bad check valve on an air conditioner, heat pump or similar HVACR equipment can show up as abnormally low or abnormally high suction line pressures, or as abnormally low or high superheat. Experts suggest using an IR heat gun or similar tempeature measuring tool to check the tempeature of the refrigerant line on each side of the valve.00:00 - What are normal pressures for R410A?00:37 - Can you pump down a 410A system?01:04 - What should my gauges read on 410A?01:39 - Can you put R22 in a R... The R410A PT chart can be used to answer questions like: What are normal operating pressures for 410A? What is the pressure of r410a at 72 degrees Fahrenheit? What should gauge read for 410A? You can also use the R-410A PT chart to adequately calculate the superheat, total superheat, and subcooling temperatures. Read also: R410a Pressure Chart High and Low Side. psi: Pound per square inch, unit of pressure. FAQ What is the normal suction pressure on a 404a walk in the freezer? The normal suction pressure on a 404 a walk in freezer is around 10-20 psig (10 is ideal) on the suction side if working properly. And the high side is about 180 or so.I shouldn't feel so tired. So overwhelmed. So underwhelmed. I shouldn't feel so much pressure. So much guilt. So much anxiety. I shouldn't expect so much from myself...Hence, R410A refrigerant is considered safer than R22 refrigerant which is why it is a direct replacement for R22 refrigerant despite being slightly higher in GWP. R410A refrigerant is also a high-pressure refrigerant. The suction pressure of R410A air conditioners is usually around 125 psi (862 kPa) which is much higher than R22 air …Table of Contents. Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, …Continue the process until the system has been determined to be leak-free. Connect the vapor-line and liquid-line pressure taps to a vacuum pump and micron meter. This step is also almost always omitted. Evacuate the refrigerant lines and indoor coil to at least 350 microns. Close off the valve to the vacuum pump and observe the micron meter.How to Use a Pool Vacuum. Visit HowStuffWorks.com to learn more about how to use a pool vacuum. Advertisement Using a pool vacuum makes the task of cleaning the floor of the pool e...Many women decide to live child-free. Yet, they often feel they owe everyone an explanation about a choice that should be entirely personal. OUR BRANDSThe low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load.to adjust valves when facing adjusting stem clockwise decreases pressure / temperature. counter-clockwise increases pressure / temperature. rawal devices, inc. call tech support: (800) 727-6447 www.rawal.com ©2020 rawal devices, inc. doc#410a-sds(R-508B) is a better replacement than Freon™ 410A. Properties Freon™ 410A is safe to use when proper storage and handling practices are followed. It is a nonflammable, low toxicity mixture of HFC-32 and HFC-125 (50/50 wt%). Freon™ 410A has been classified as A1 by ASHRAE and assigned the ASHRAE number of R-410A. It has beenR410A. R454B. Refrigeration Equipment. Air Cooled Condensers. Chillers. Condensing Units. Cooling Towers. Fluid Coolers. Ice Machines & Parts. Refrigerators & Freezers. ... Pressure/Temperature Chart. Temperature (F) R-22 R-410A R-12 R-134a R-404A R-507A R-407A R-407C R-427A R-422B R-422D R-407F R-448A R-421A R-513A R-449A R …Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold. The TXV is backed all the way …Aug 8, 2020 ... In this HVAC Video, I Show SEVERELY UNDERCHARGED, UNDERCHARGED, CORRECTLY CHARGED, and OVERCHARGED Scenarios on a Running R-410A Refrigerant ...These liquid-line restrictions all cause the evaporator, compressor, and condenser to be starved of refrigerant. This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control;number for specific refrigerant). R-410A is a high-pressure refrigerant that requires the other components of the system to be rated for R-410A. For compressor lubrication, the refrigerant requires POE oil. Tranes ’ BCHC and BCVC 024-090 blower coil air hand ler products have also b een redesigned for use with the higher pressures of R-410A.R410A PRESSURE-TEMPERATURE CHART Saturation Pressure-Temperature Data for R410A (psig)* ECLPC-1 Rev 1 – 02/22. Created Date: 2/25/2022 1:24:53 PM ...If the suction pressure is 45 psi, (which converts to 22 ° F) and the suction temp is 32 ° F, the system still has 10 ° F of superheat. The fact that these readings are normal indicates the low suction pressure is not caused by low refrigerant, but insufficient heat getting to the evaporator. CAUSE #2: Defective, plugged, or undersized ...FreonTM 410A. Refrigerant (R-410A) Piping Guide for FreonTM 410A (ENG Units) Technical Information. Suction Line Size—Evaporator to Compressor. 50 °F through 30 …

Cleaning services are always in demand and there are many different segments in the industry, here is how to start a pressure washing business. If you buy something through our lin.... How did heather o'rourke die

suction pressure for 410a

Calculate. This free online tool allows HVAC professionals to quickly calculate Superheat and Subcooling measurements for both R22 & R410A refrigerants.The R410A PT chart can be used to answer questions like: What are normal operating pressures for 410A? What is the pressure of r410a at 72 degrees Fahrenheit? What should gauge read for 410A? You can also use the R-410A PT chart to adequately calculate the superheat, total superheat, and subcooling temperatures. Never install suction- line filter drier in the liquid- line of an R-410A system.! CAUTION 7. If suction-line filter drier was installed for system clean up, operate system for 10 hr. Monitor pressure drop across drier. If pressure drop exceeds 3 psig, replace suction-line and liquid-line filter driers. Be sure to purge system with dry nitrogen ... In this HVAC Training Video, I Show If You Can Check The Refrigerant Charge on an Inverter Mini-Split Ductless Unit on a Service Call by measuring superheat ...R-410A Pressure-temperature chart Click anywhere on this document to return to Refrigerant Gas Properties information at InspectApedia.com This chart was provided by the Bonneville Power Authority,Liposuction is the removal of excess body fat by suction using special surgical equipment. A plastic surgeon typically does the surgery. Liposuction is the removal of excess body f...R-410A system with TXV Readings: Outdoor dB: 95 Outdoor wB: 87 Indoor dB: 82 Indoor wB: 72 Suction Pressure: 164 Suction Temp: 61 Discharge Press: 350 Discharge temp: 96 Supply temperature: 66 So, I've got 11 degrees of Subcooling, which means the charge is about right (based on the chart on the unit), but only 2 degrees of …Here we will learn the R410A Pressure-Temperature Chart. R410A is very commonly used refrigerant that is known as AZ-20”, “Genetron R410A”, “Puron. It is patented by Honeywell. It is mostly used freon in AC systems and works as a replacement for R22. Here we will make an R410A Pressure-Temperature Chart that will help you …Liquid pressure for 410a on a 85 degree day is: 255.4psi. Vapor pressure for 410a on a 85 degree day is: 254.6 psi. Example 2. What should the 410a pressures on a 50, 65, 70 degree day be? On a 50 degree day. Liquid pressure: 143.2 psi. Vapor pressure: 142.6 psi. On a 65 degree day. Liquid pressure:185.8psi. Vapor pressure: 185.2 psi.Sep 11, 2021 ... Low Outdoor Temp, "CHECK THE REFRIGERANT CHARGE" in the Cold! · 64K views ; Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps,...I installed a new 410a complete system with new Orfice coil and new lineset. 70 degrees on install date and initial start up. Suction pressure was 110 and high side of 280. It ran for about 15 minutes. I added a little freon and the high side shot up to 425.I shouldn't feel so tired. So overwhelmed. So underwhelmed. I shouldn't feel so much pressure. So much guilt. So much anxiety. I shouldn't expect so much from myself...I would think we could have a thermostat that could do this: Heating mode: outside temp >65F: Run AUX only - lock out compressor (avoid high pressure) outside temp >10F and <65F: Run compressor and AUX as needed. outside temp <10F: Run AUX only - lock out compressor (avoid defrost cycling) Cooling mode: outside temp <60F: lock …psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114Jan 27, 2021 · Suction Pressure / EVAP DTD Rule of Thumb Another common old school rule of thumb is suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20˚-25˚ suction saturation below outdoor ambient. .